WH-ADC0912K6E5 Panasonic WH-ADC0912K6E5 Vnitřní jednotka T-CAP All in One 1zónová 9 - 12 kW 185L 230V
Panasonic WH-ADC0912K6E5 Vnitřní jednotka T-CAP All in One 1zónová 9 - 12 kW 185L 230V
Jednofázový split systém Aquarea T‑CAP All in One
generace K. Vytápění a chlazení · R32
Volitelný Wi-Fi adaptér (CZ-TAW1B)
Vnitřní jednotka (V × Š × H): 1 642 x 599 x 602 mm
Provozní rozsah až do −28 °C při vytápění
Energy efficiency: A+++ in heating at 35 °C and A+ in DHW / “A” water pump
with variable speed / Stainless steel DHW tank with U-Vacua™ insulation
panel / Built-in flow meter.
Flexibility: 598 x 600 footprint / Built-in magnetic water filter.
Comfort: Constant capacity down to -20 °C / Operating range down to
-28 °C / 60 °C hot water even at -10 °C outside temperature.
Control: Optimised user interface and improved features (2 zone control,bivalent control).
Connectivity: Optional Aquarea Smart and Service Cloud and integration into BMS projects.
Indoor unit WH-ADC0912K6E5 WH-ADC0912K6E5 WH-ADC0912K9E8*** WH-ADC0912K9E8***
Sound pressure Heat / Cool dB(A) 33 / 33 33 / 33 33 / 33 33 / 33
Dimension H x W x D mm 1 642 x 599 x 602 1 642 x 599 x 602 1 642 x 599 x 602 1 642 x 599 x 602
Net weight kg 101 101 — —
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼
A class pump
Number of speeds Variable Speed Variable Speed Variable Speed Variable Speed
Input power (Min / Max) W — / 145 — / 145 — / 145 — / 145
Heating water flow (ΔT=5 K. 35 °C) L/min 25,8 34,4 25,8 34,4
Water volume L 185 185 185 185
Maximum DHW temperature °C 65 65 65 65
Material inside tank Stainless steel Stainless steel Stainless steel Stainless steel
Tapping profile according EN16147 L L L L
DHW tank ERP efficiency average / warm / cold 2) A+ to F A / A+ / A A / A+ / A A / A+ / A A / A+ / A
DHW tank ERP average climate η / COPdHW ηwh % / COPdHW 112 / 2,80 112 / 2,80 112 / 2,80 112 / 2,80
DHW tank ERP warm climate η / COPdHW ηwh % / COPdHW 132 / 3,30 132 / 3,30 132 / 3,30 132 / 3,30
DHW tank ERP cold climate η / COPdHW ηwh % / COPdHW 88 / 2,20 88 / 2,20 88 / 2,20 88 / 2,20
Electrical information WH-ADC0912K6E5 WH-ADC0912K6E5 WH-ADC0912K9E8*** WH-ADC0912K9E8***
Electric backup heater kW 6,00 6,00 9,00 9,00
Recommended fuse A 30 / 30 30 / 30 — / — — / —
Recommended minimum cable size, supply 1 / 2 4) mm² 3 x 4,0 / 3 x 4,0 3 x 4,0 / 3 x 4,0 — / — — / —